The fusion splice-on connector is field installable and provides easy quick, reliable, permanent field terminations, complying with international standards, such as IEC 61300 series, and Telcordia GR-326-CORE/GR-1081-CORE. It provides more stable quality and performance than that of mechanical field installable types of connectors. Its fiber and field fiber from drop/patchcord cable can be aligned and spliced by using fusion splicers to terminate any types of fibers in the optical cable. The splice point is protected with heat shrink protection sleeve and located in the connector body. It allows installers to reduce service delivery/operation and maintenance time. The fusion splice-on connector (FSOC) is quick, easy and reliable solution for the last mile of FTTH (Fiber to the Home) and data center area. As it is field installable, it eliminates excess cable length and because of fusion splicing, there is no need of field mountable connector which requires high precision skills.
← Scroll left and right →
← Scroll left and right →
Field installable technology
Superior optical, mechanical and environmental performance
Splicing point and its protective tube located inside the connector
No cable slack required
Strong tensile (4.5~6.8kgf) enables outdoor deployment
Improvement of quality and reliability reduces maintenance cost and labor cost dramatically
Reduction of installation cost
Field stripping available for the SOC
Pre-stripped/pre-cleaved available optionally
Compliant with Telcordia GR-326-CORE
← Scroll left and right →
The fusion splice-on connector has many types such as SC, LC, ST and FC, consisting of ferrule assembly, protected fiber stub of defined length, housing, stop ring, protection sleeve, boot and so on. Below figure shows the structure and its components.
The typical loss of the physical contact mated in the adapter can be 0.1 dB. Fusion splicing attenuation is typically 0.02 dB, and maximum is 0.05 dB. Therefore total expected loss is in the range of 0.12 dB to 0.15 dB. Expected return loss is over 55dB (UPC) and over 60dB (APC) respectively. It can be adapted to analog networks (≥55dB) with no signal interference and no noise. Types of the alignment methods are IPAAS Core, Fixed V-groove and Active clad. Most importantly, fiber angles and cleaved fiber ends can be seen on the fusion splicer while splicing and the splicing point can be protected with heat shrinkable tubes.
← Scroll left and right →
Process | Specifications (at 1310nm and 1550nm) | |
---|---|---|
Insertion Loss | Avg. | ≤0.2dB |
Max. | ≤0.3dB | |
Return Loss | Min. | >50dB (UPC), >60dB (APC) |
← Scroll left and right →
Test | Conformance | Method / Condition | Specifications |
---|---|---|---|
Mating Durability | IEC 61300-2-2 / GR-326-CORE, 4.4.3.8 | No. of cycles: 200 | Loss Increase ≤ 0.3dB Return Loss Decrease ≤ 5dB |
Vibration | IEC 61300-2-1 / GR-326-CORE, 4.4.3.1 |
Freq. Range: 10Hz ~ 55Hz Duration: 2h/axis Sweep rate: 1 octave/min Amplitude: 1.5mm |
Loss Increase ≤ 0.3dB Return Loss Decrease ≤ 5dB |
Impact | IEC 61300-2-12 / GR-326-CORE, 4.4.3.7 | 8 drops 1.5m drop height |
Loss Increase ≤ 0.3dB Return Loss Decrease ≤ 5dB |
Proof (2.0mm/3.0mm Cord Types only) |
IEC 61300-2-51 / GR-326-CORE, 4.4.3.5 | Straight pull, 0°, 6.8kgf, 5 sec / Side pull, 90°, 2.3kgf, 5 sec | Loss Increase ≤ 0.5dB Return Loss Decrease ≤ 5dB |
Transmission with Applied Tensile Load (2.0mm/3.0mm Cord Types only) |
GR-326-CORE, 4.4.2.2 | Loads: 2.0kgf at 0°/90°, 0.25kgf at 135° | Loss Increase ≤ 0.3dB Return Loss Decrease ≤ 5dB |
Thermal Cycle | GR-326-CORE, 4.4.2.2 | -40°C±2°C to 75°C±2°C, 21 cycles, Dwell time: 1 hr at 23°C±2°C, Transition time: 1 hr | Loss Increase ≤ 0.3dB Return Loss Decrease ≤ 5dB |
End face Geometry | Telcordia GR-326-CORE, 4.4.5 | Interferometer measurement |
Apex offset: <50μm Radius of Curvature: 7~25mm (UPC) / 5~12mm(APC) Undercut/Protrusion: UPC: Undercut: -0.02R3+1.3R2-31R+325, Protrusion: ≤50nm, APC: Undercut/Protrusion ≤100nm APC Angular Tolerance: 7.850~8.050 degree |
← Scroll left and right →
Model |
Image |
Description | Specifications |
FSOC-SC-09 |
|
SC type Polishing type: UPC, APC Fiber type: SM, MM Applicable cable diameter: 0.9mm Dimensions: 57x9x8mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB | |
FSOC-SC-HB |
|
SC Hard boot type Polishing type: UPC, APC Fiber type: SM, MM Applicable cable: 2x3mm/3mm drop cables Dimensions: 56.5x9x8mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB Straight pull, 0°: 4.5kgf, Side pull, 90°: 2.3kgf | |
FSOC-SC-SB |
|
SC Soft boot type Polishing type: UPC, APC Fiber type: SM, MM Applicable cable: 2mm/3mm cords Dimensions: 62x9x8mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB Straight pull, 0°: 6.8kgf, Side pull, 90°: 2.3kgf |
← Scroll left and right →
Model |
Image |
Description |
Specifications |
FSOC-LC-09 |
LC type Polishing type: UPC, APC Fiber type: SM, MM Applicable cable diameter: 0.9mm Dimensions: 45.7x10.3x5.5mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB |
||
FSOC-LC-20 |
|
SC Soft boot type Polishing type: UPC, APC Fiber type: SM, MM Applicable cable: 2mm cord Dimensions: 62x9x8mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB Straight pull, 0°: 6.8kgf, Side pull, 90°: 2.3kgf |
← Scroll left and right →
Model |
Image |
Description |
Specifications |
FSOC-FC-09 |
|
FC type Polishing type: UPC, APC Fiber type: SM, MM Applicable cable diameter: 0.9mm Dimensions: 54x10x10mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB |
|
FSOC-FC-30 |
|
FC Hard boot type Polishing type: UPC, APC Fiber type: SM, MM Applicable cable: 3mm cord Dimensions: 59x10x10mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB Straight pull, 0°: 4.5kgf, Side pull, 90°: 2.3kg |
← Scroll left and right →
Model |
Image |
Description |
Specifications |
FSOC-ST-09 |
|
ST 0.9mm type Polishing type: UPC Fiber type: SM, MM Applicable cable diameter: 0.9mm Dimensions: 61.3x9.6x9.6mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB |
|
FSOC-ST-30 |
|
ST 30 boot type Polishing type: UPC Fiber type: SM, MM Applicable cable: 3mm cord Dimensions: 61.6x9.6x9.6mm IL: Typ. 0.15dB, Max. 0.3dB RL: SM: ≥55dB (UPC), ≥60dB(APC), MM: ≥30dB Straight pull, 0°: 4.5kgf, Side pull, 90°: 2.3kgf |